Ethernet Cables & Fiber

Differences among CAT5e, CAT6, CAT6A, CAT7, CAT8 Ethernet cable

Ethernet cables physically connect local area networks via eight internally twisted and shielded wires. The wires come in either solid or stranded configurations. Solid wires deliver better performance but are more fragile and prone to break.

Understanding the categories of Ethernet cabling is crucial to selecting the right one for your networking needs.

Twisted-pair Ethernet cables have progressively improved performance over consecutive generations. Tighter winding, complex sheathing, and shielding have resulted in the advancement of Ethernet cable categories. Here is a summary of the different categories of Ethernet cables.

CAT 5e

  • CAT5e is Enhanced CAT 5 and is an improvement to the standard CAT 5. CAT 5e is a Class D cable operating at a data transmission bandwidth frequency of up to 100 MHz and a 1000Mbps data transfer rate with a maximum range of 100 meters. CAT 5e can ideally be used for 1Gbit applications.
  • CAT 5e has completely replaced its predecessor, CAT 5. It is preferred in home and office networks with moderate data transfers between 10-100 meters due to its flexibility, low cost, ease of crimping and Gigabit Ethernet capability.

CAT 6

  • CAT 6 is a Class E cable. Supports data transfer rates of up to 10Gbps at a peak bandwidth frequency of 250 MHz. CAT 6 is certified for a maximum range of 100 meters, though due to crosstalk at 10Gbps it is reliably used for a maximum of 55 meters’ transmissions.
  • CAT 6 is more tightly wound than CAT 5e at more than 2 twists/cm, featuring a tougher outer sheath and central pair separator spine to reduce Alien and near crosstalk, and increase rigidity.

    CAT 6 lies in a grey area between the cost-effectiveness of CAT 5e at Gigabit speed and the significant performance improvement of CAT 6A.

CAT 6A

  • The A stands for “Augmented.” CAT 6A cables support 10Gbps data transfers at 500 MHz - twice the frequency of CAT 6 and supports 10Gbps speeds to 100 meters. The cable has a thicker sheath then CAT 6, reducing crosstalk and increasing SNR at high data speeds. The CAT 6A is a Class Ea cable owing to the thick sheath and even stiffer pair separator spine reducing its flexibility.
  • Due to its low flexibility and tough sheath, CAT 6A cables are generally used for industrial applications, outdoor and large-scale networks requiring high data transfers over long distances.

CAT 7

  • CAT 7 is a stiff Class F cable, with separate twisted pair shielding and additional overall outer shielding beneath a tough outer Sheath. Tests have shown that CAT 7 can transmit at a 600 MHz bandwidth frequency, 10Gbps to 100 meters, 40Gbps to 50 meters and 100Gbps to 15 meters.
  • Shielding on the CAT 7 cable needs to be grounded especially at high transfer speeds. It requires GigaGate45 connectors, and modern infrastructure to realize the full speed. CAT 7A is also available, sharing most features with CAT 7, but able to transmit at 1 GHz bandwidth frequency.

    CAT 7 is almost exclusively used in data centers and lager high-throughput network.

CAT 8

  • CAT 8 is a heavily shielded Class II cable that is yet to hit mainstream after extensive testing and standardization. CAT 8 can support bandwidths of up to 2 GHz, and manage a data transfer rate of 25Gbps and 40Gbps on a maximum cable length of 30 meters.
  • CAT 8 is intended for use in high-performance server rooms and data centers.

Ethernet Cables for Local Area Networks

Ethernet cables are a type of networking cable that are used to connect electronic devices. They are widely used to create wired networks of varying sizes, specifications, and complexity. When they are terminated with their complementary Ethernet connector and Ethernet ports. Ethernet cables are capable of supporting data transfer of varying speed and throughput. Computers and other hardwired networked devices use Ethernet cables to securely share files and communicate efficiently. They are one of the early building blocks or media specified in the Physical Layer (PHY) of many well-known network protocols as well as a key component in providing internet connectivity.

Quality RoHS compatible Ethernet cables and connectors. Our extensive range of Ethernet cables, connectors, and other accessories are manufactured to the highest standards for consistent, reliable performance. All materials and fabrication techniques used are fully compliant with the following legislation:

What is Ethernet?

Ethernet is a wired networking technology that is used to devise and build a range of local area networks (LANs) and wide-area networks (WANs). It is also capable of supporting metropolitan area networking (MAN), amenity-like expansive networking that connects and serves computers in large numbers and on a scale equivalent to a geographic metropolitan area. It is used in almost every sector of the industry as well as domestic and consumer computing. It also integrates well with WiFi as it is capable of the internetworking necessary for supporting the Internet Protocol.

Ethernet provides physical-space connectivity between computers and devices. The networks created can support a high number of nodes securely and over long distances. It was first standardized in the 1980s with the release of the 802.3 protocol by the Institute of Electrical and Electronics Engineers (IEEE). Since its introduction, it has been further revised and refined with an increase in bit rates, security, and a broadening of its applications while remaining largely backward compatible. Contemporary bit rates can exceed 400 Gbit per second. The standardization of Ethernet has also defined the physical space with all compatible hardware carrying the same standardized ports.

How does Ethernet work?

Ethernet data transfer works by breaking down the data into smaller units known as frames. Each frame carries identifying addresses for the data source and destination. The frames also have an error-checking component that can eliminate damaged frames and trigger their re-transmission.

Ethernet structure and functionality span Layers 1 and 2 of the seven-layer Open Systems Interconnection model (OSI model) for telecommunication and computing systems. This means that it is concerned with the transfer of data between participant nodes in a network via its physical layer which includes Ethernet cables.

Every piece of Ethernet hardware and components has a unique identifier (assigned by the manufacturer) which serves to identify them and be used as a network address. This burned-in address, known as a Media Access Control (MAC) address consists of 6 sets of hexadecimal digits usually separated by hyphens.

The MAC address is used to transfer data frames between nodes correctly. The MAC sublayer oversees which address is allowed to see the transferred frames using collision avoidance protocols.

Ethernet cables are twisted-pair cables

Ethernet was initially developed using coaxial cables rather than the recognizable twisted pair cable that is now in widespread use. 10Base5 Ethernet or thicknet was expensive and difficult to install and maintain, often due to the inflexibility of the coax used.

Contemporary Ethernet cable uses twisted pair cabling. This cable type was invented by Alexander Graham Bell and is made up of paired conducting wires that are twisted together to reduce electromagnetic leakage, noise, and cross-talk.

A twisted-pair Ethernet cable consists of 8 wires that are color-coded and arranged in 4 twisted-pairs. Their color and arrangement are important for terminating Ethernet cables with 8-position modular connectors, like the RJ45 connector.

Twisted pairs are used to create balanced lines which are transmission lines made up of two conductors of the same type and impedance. Because of their proximity, the paired wires will be subjected to the same type and level of EM interference as signals pass along them from the source and will be far easier to cancel out at the receiving end (common mode rejection). Balanced circuits that use these lines are efficient at rejecting electromagnetic interference and are capable of faster and more precise data transfer. If the pairing fails or the system is unbalanced in any way, common-mode rejection fails and the system becomes vulnerable to interference.

The wires may be shielded twisted pair (STP) or unshielded twisted pair (UTP). Shielded or screened wires have foil or braided shielding that is conductive and adds additional protection against electromagnetic interference. The choice of cable may be specified by a networking protocol to achieve specific speeds and performance or selected according to the level of shielding an application requires. The shielding of the cable contributes to its categorization as outlined for each cable type below. The key shielding types are:

  • Individual shield (U/FTP)

These twisted pairs or quads have individual aluminum foil shielding. They are also known as “shielded twisted pairs” or “pair in metal foil.” They are effective in preventing leakage of electromagnetic energy and crosstalk.

  • Overall shield (F/UTP, S/UTP, and SF/UTP)

This type of shielding also known as shielded twisted pair, foiled twisted pair, or screened twisted pair, covers all of the unshielded pairs within an Ethernet cable with foil, braided shield, or a combination of both.

  • Individual and overall shield (F/FTP, S/FTP, and SF/FTP)

With this type of twisted pair cable, there is not only foiled shielding of individual wires within the pairs, but also an overall outer foil or braided shield. It is also known as screened foiled twisted pair, or fully shielded twisted pair. This type of Ethernet twisted pair cable is highly insulated against electromagnetic interference.

  • The twist rate of twisted pairs

Twisted pairs have a specified pitch or rate of twisting, measured in twists per meter. This helps to determine the arrangement of the pairs within an Ethernet cable. The pairs that make up a cable must have different twist rates to preserve the benefits of twisting. Adjacent twisted pairs with a like pitch are avoided.

  • The twisted pairs within an Ethernet cable are color-coded

A color-coding system is used to identify the individual conducting wires that make up an Ethernet cable. The insulating plastic jacket that surrounds the wires carries the colors, which also guide the wiring of these cables following various standards and specifications.

There are up to 25 different color combinations. Each twisted pair is made up of a major color and minor color which are selected from two different groups. The major colors include white, red, black, yellow, and violet and the secondary colors include blue, orange, green, brown, and slate. The major wire carries a solid block color, and the minor wire in the pair is white with colored stripes or rings.

Types of Ethernet cables

There are 8 types of Ethernet cables with the earlier Ethernet cable types being used for telephone wiring, ISDN, and token ring. The most widely used types of Ethernet cables are Category 5e and 6 cables and their variants which we describe below.

Category 6 Ethernet cable

Cat 6 Ethernet cable is a twisted pair cable that has become an industry standard. It is manufactured to deliver consistent performance at frequencies of up to 250 MHz. It was devised as an improvement on the existing CAT5 cable to improve data speeds. It is backward compatible with Category 5 and 5e (Cat 5e) cable. It is widely used in network physical layers for computing as well as audiovisual and telco applications. Category 6 cable has greater shielding and protection against unwanted noise and crosstalk. Its physical and electrical characteristics are outlined in several specifications including:

  • ISO/IEC 11801 global cabling standard has been extended to publish specifications for Category 6A cable which works with newer connecting hardware for enhanced performance.
  • ANSI/TIA-568.2-D is a standard produced by the Copper Cabling Subcommittee of the Telecommunications Industry Association (TIA). This standard specifies the transmission and mechanical requirements for category 6 cable and its variants.

The performance of Category 6 cable means that it can be used for higher speeds of Ethernet including Gigabit Ethernet. It is suitable for supporting 10 Base-T, 100 Base-T, 1000 Base-T, and 10G Base-T.

Category 6 cable physical specifications
Cat6 UTP horizontal cable uses several strategies to improve its performance at higher frequencies and support speeds of up to 1000 Mbits per second over long runs. They are most notably:

  • Thicker wire
  • More shielding
  • The greater pitch of the twisted pairs

Category 6 cable consists of 4 twisted pairs laid up in a cross arrangement. The center wires of the twisted pairs are solid, plain copper wire with an AWG of 23. The conductor diameter is 0.57 millimeters (0.022 inches).
The copper wire is insulated with high-density polyethylene (HDPE) jacketing for an outer diameter of 1.1 millimeters (0.043 inches). The drain wire carried by this cable is 0.4 millimeters (0.0157) of tinned copper. The twisted pairs are covered by an aluminum foil screen and PVC jacketing for an overall diameter of 7.3 millimeters (0.287) inches.

CAT5 FTP cable has a temperature range is -10 to +60 degrees Celsius (-14 to 140 degrees Fahrenheit). It has a minimum bend radius for installation of 40mm (1.57 inches). It has a bend radius of 25 millimeters (1 inch).

The color-coding of the four twisted pairs in Category 5 Ethernet cable is as follows:

  • Pair 1 Blue / Striped Blue
  • Pair 2 Orange / Striped Orange
  • Pair 3 Green / Striped Green
  • Pair 4 Brown / Striped Brown

Category 5 cable electrical specifications

  • Category 5 Ethernet cable is rated for frequencies up to 250 MHz.
  • It is known for its high signal to noise ratio (SNR), due to the use of balanced lines.
  • Its impedance is 85 to 115 Ohms. depending on the frequency at which it is used.
  • The velocity of propagation of category 6 cable is 68 percent.
  • At 250 MHz, the attenuation of Cat5 cable is 3.1 dB/10m.
[D] Category 6A Ethernet cable

This variant of Category 6 cable is labeled A for Augmented with standards for its specifications and performance updated as recently as 2008. It is also known as Category 6E Ethernet cable. It is a shielded Ethernet cable with a bandwidth frequency of 500 MHz, twice that of the standard Cat6 cable. Cat6a cable has proven advantageous for supporting higher transmission speeds (10,000 Mbits per second / 10 Gigabits per second) over longer lengths of cable. The careful shielding almost completely screens out electromagnetic interference and crosstalk, but also means that this form of Ethernet cable is less flexible.

Why are Ethernet cables important?

Ethernet cables for 802.3 networking

Ethernet network cables carry Ethernet and the performance of the different cable types needs to be precisely matched to the type of Ethernet being deployed. As the IEEE 802.3 standard has been developed and expanded, newer forms of Ethernet over twisted pair or classic Ethernet have emerged that are capable of faster speeds and less error-prone performance. These types of Fast Ethernet and Gigabit Ethernet include:

  • What is 100BASE-T?

This form of Ethernet was introduced in the mid-1990s as the 802.3u standard and requires cables that are Category 5 and above. The networks built using this form of Fast Ethernet are star networks centered around a central hub. The shared media local area networks (LANs) created with Fast Ethernet are comprised of segments that can have cables of up to 100 meters (328 feet) in length. Connections are duplex, with twisted pairs are used separately to serve each direction with bidirectional data throughput of 100 Mbit per second.

  • What is 1000BASE-T?

1000Base-T is Gigabit Ethernet. This form of internet is capable of data transfer at a rate of 1 Gigabit per second. It is specified by the 802.3b standard which superseded Fast Ethernet in 1999. It has largely replaced Fast Ethernet for LAN networking due to its speed and innovations in hardware and cables. Category 5, Category 5e, and Category 6 cables can support Gigabit Ethernet with cable runs of up to 100 meters in length performing optimally. 1000BASE-T uses all four twisted pairs within the cable for simultaneous bidirectional data transmissions. This Ethernet version is used for broadband applications and data centers.

  • What is 10GBASE-T?

Category 6 cable and above is capable of supporting 10 Gigabit Ethernet which has a data rate that is ten times the Gigabit Ethernet level. It also can use fiber-optic cable, but copper is cheaper and massively impacts installation costs. It was first introduced in 2002 as IEEE 802.3ae. 10 Gigabit Ethernet has taken time to become widely adopted due to hardware costs (particularly the ports). It delivers Ethernet frames across full-duplex point-to-point links with lower latency, and over cable lengths of up to 100 meters (328 feet). It is also fully backward compatible with standard Gigabit Ethernet.

Ethernet cables are compatible with a range of key network components.

What is an Ethernet connector?
The RJ45 or Registered Jack 45 connector is the standard connector for terminating Ethernet cables. They have a familiar appearance that is much like a larger analog telephone plug. The connector design and specification were initially developed in the late 1970s in accordance with telecommunications specifications.

The male plug that is used to terminate Ethernet cables has a row of 8 metal pins that retain the twisted pair wires from the cable. Within the connector, the 4 twisted pairs have an 8 Position, 8 Contact (8P8C) configuration. RJ45 connectors have to be carefully wired as if the ordering of the wires is incorrect, the cable will not function. For bidirectional data trafficking, the wires are divided into transmit and receive wires. The ordering of the wires is specified by the wiring codes T-568A and T-568B, which can also be used to classify cable. They differ only in the arrangement of the orange twisted pair wires. Both color patterns are recognized by the ANSI/TIA-568-C standard but Federal cabling undertaken for the US Government requires only T-568A wiring.

What are Ethernet switches?
These network switches or hubs are used in computer networking for receiving and forwarding the data packets or frames that are transferred within a network. Ethernet switches are the most common type of network It is a unit that contains multiple ports and relies on MAC addresses for correctly forwarding the data, only forwarding to the port that is connected to the recipient device.

What is an Ethernet router?
Routers are electronic devices that are also able to send and forward information in computer networks. Ethernet ports are a common port on routers, which allow a single IP address to be shared among several network devices. They are a key interface between wired and wireless networking and connectivity as a router can send and receive data via Ethernet cables and broadcast the data (or access the internet) wirelessly via WiFi.

Frequently asked questions

  • How do you wire an Ethernet connector?

To correctly terminate an Ethernet patch cable you will require a suitable length of Category 5 or 6 cable and RJ45 connectors as well as wire cutters for cutting and stripping the cable, and an RJ45 Modular Connector Crimper.

  1. The Ethernet cable must first be prepared by cutting it to length and stripping off 2 inches of the cable sheath.
  2. The twisted pairs within the cable should be spread out according to the wiring pattern that is required.
  3. The individual wires should be trimmed to an equal length and stripped of their polyethylene insulation leaving between ½ and ¾ of an inch (12 to 19 millimeters) of copper conducting wire exposed.
  4. The exposed wires should be inserted in order into the front of the RJ45 plus. The sheath of the Ethernet cable should follow by about ½ inch (12 millimeters).
  5. The connector can now be crimped with the RJ45 crimping tool. The wires are held down by pins and the cable sheath is also crimped for a secure hold.
  • What is a straight-through Ethernet cable?

A straight-through Ethernet cable is one that is used to connect a computer to an Ethernet switch, hub, or router. Straight-through cables connect devices of different types.

  • What is a patch Ethernet cable?

Patch cables are used to patch in or connect one device to another for routing a signal. It is now widely used as a generic term to describe Ethernet cables.

  • What is a crossover Ethernet cable?

Crossover cables are used to connect computers directly. They are used to create Ethernet connections between like devices.

  • Does Ethernet cable length matter?

Like other forms of cable, Ethernet is subject to signal loss along its length. This is known as attenuation and varies between cable types and manufacturers. Ethernet cable runs are normally limited to 100 meters (328 feet) as beyond this length attenuation becomes significant and will impact network performance.

  • ptical fiber is a high-clarity fully transparent fiber made from strands of glass or certain plastics that have been drawn out to be as thin as human hair. Like radio frequency signal transmission down a copper wire, fiber networking uses light as its carrier wave, using a range of modulation techniques to encode and transmit data. Unlike radio frequency connectivity, fiber-optic networking is immune to electromagnetic interference. Fiber has demonstrable efficacy for supporting secure,high-speed, high-bandwidth connectivity over significant distances with minimal signal loss.

Fiber is capable of transferring a variety of data including voice, video, audio, and IP data packets. Current applications of this technology include telecommunications, broadband internet connectivity, and cable television

The history of fiber networks.

The development of fiber optic technology spans over 50 years and can be traced back to the invention of the laser. Before that Alexander Graham Bell created a device, named the photophone that could transmit sound on a beam of light. The use of optical fiber for communications was first proposed in the mid-1960s with the suggestion that the photons of light could be guided and directed in a similar way to electrons in a copper cable.

Early fiber optic technology was affected by high levels of losses from the prototype optical fibers and progress was only made in the 1970s where methods were found to drastically reduce losses, making fiber optics viable for its first, experimental network deployments from 1975.

Progress in fiber optic networking proceeded on a step-wise basis to its present levels of efficacy and performance. The bit rate (B) and repeater spacing (L) for these networks increased greatly, leveling off to where it is today.

  1. First-generation fiber-optic networks used multimode fiber and operated at 850 nm using a Gallium Arsenide (GaAs) semiconductor laser. These networking components were commercially released in the early 1980s and supported speeds of up to 45 Mbit/s with repeater spacing of up to 10 kilometers (6.21 miles), far greater than comparable coax systems at that time.

  1. Second-generation fiber-optic networks or lightwave systems were capable of achieving bit rates of up to 1.7 Gbit/s with an uplift to repeater length of 50 kilometers (31 miles). Both first and second generations systems were specified by the International Telecommunications Union (ITU), with the second-gen network operating at 300nm in single mode.

  1. Third-generation fiber-optic networks were limited by significant losses due to increasing repeater spacing at 300 nm. But by 1992, single-mode systems were commercially available that operated at 2.5 Gbit/s reliably and up to 10 Gbit/s in experimental settings. Third-gen optical systems were able to operate at 550 nm. Repeaters to forward the transmitted signals needed to be installed every 70 to 80 kilometers. Further developments in the technology introduced fiber amplifiers (in 1989) that can boost repeater spacing. Also, Wavelength Division Multiplexing (WDM) was capable of boosting the bit rate that could be achieved. These enhancements converged with the emergency of fourth-generation lightwave systems.

  1. Fourth-generation fiber-optic networks use amplifiers and multiplexing to boost speeds above 5 Gbit/s and repeater distances in the hundreds of kilometers.

  1. Fifth-generation or fifth-phase fiber-optic networks include the contemporary forms of fiber networking which have developed in a variety of directions including long-haul, high-capacity, multimode, optical/electrical/optical (O/E/O), and multi-channel networking. Also, extremely low-loss fibers have been developed such as the dry or low water peak fiber. Contemporary lightwave systems have tens of channels with end-user networking speeds of tens of Gigabits per second. Network topography has also matured with the development of optical transport networks (OTNs). The ITU has released successive standards for OTNs that have supported a transition in fiber technology from short distance links to long-distance backbone links over optical paths of 2000 kilometers.

Key fiber network components

[A] Optical transmitters: Optical transmitters receive an electrical input and convert it into an optical signal that is transmitted down the fiber cable. These transmitters are LED or laser diode semiconductor devices that are capable of operating at the required wavelength with high-frequency modulation. Ideally, the transmitters are small and compact and integrate both the electrical and optical connectors.

  • Laser diodes that produce coherent light (light with a fixed phase wave) are highly efficient, with little loss. They produce a directional output with effective coupling to the attached fiber cable. Vertical Cavity Surface Emitting Laser (VCSEL) devices have enhanced speed, power, and spectral performance compared to LED devices. Modulation is achieved by the current that is directly applied to the transmitter.

  • Gallium Arsenide LED optical transmitters are cheaper and produce incoherent light, which has a wider and more variable spectral width. They are less efficient than their laser counterparts with only a small proportion of the input power converted into launched power via the fiber cable.

[B] Optical receivers are devices that are able to receive an optical signal via a fiber connection and convert it into an electrical output signal. These devices used the photoelectric effect, where electron emissions are generated by transmitted light hitting diode material within the receiver.

The optical-electrical converter portion of the receiver is coupled to transimpedance and limiting amplifiers that assist in producing a viable digital output signal as it can become attenuated by the conversion process. Other signal processing steps may also be applied to the signal recovered by these devices depending on where the transmitted light was coherent or incoherent.

[C] Optical fiber cable is comprised of flexible thin, glass, or plastic fibers that are bundled and clad to guide light that is transmitted down them. The cables use total internal reflection fast, directional transmission. A typical fiber cable is comprised of a core of fibers, that are clad in low refractive material and sealed in a protective outer jacket known as a buffer.

Despite being made up of hair-like glass fibers these cables are resilient and can be routed, buried, or submerged similarly to copper cable. Once installed their maintenance requirements are low.

There are two key classes of optical fiber used in networking.

  1. Multi-mode optical fiber cable has a core that has a larger diameter (50 micrometers) meaning that it can operate effectively with LED optical transmitters that use incoherent light and have poorer precision. Because of the equipment used with it, multi-mode fiber can be affected by distortion and attenuation, which limits the bandwidth of links formed with this cable.

  2. Single-mode optical fiber has a diameter of fewer than 10 micrometers but requires precision network components for more accurate data transmission and more robust, longer-distance links.

Like coax, both types of fiber are available in a range of grades depending on the wavelength of light they use and their attenuation. The quality of the fiber (particularly the presence of water and other impurities) and its bend radius are key determinants of the performance of the cable and its level of attenuation.

[D] Amplifiers: As mentioned in the history of Fiber networking above, distortion and attention of transmitted signals were originally key limiters of the utility of fiber. An initial solution for this problem was the use of optoelectronic repeaters that would receive and retransmit the optical signal at regular intervals. These devices would have to be installed at regular intervals (every 20 kilometers / 12 miles) along a cable run which proved expensive.

Repeaters have been largely superseded by amplifiers that do not need to convert the signal to an electrical one before enhancing it and sending it on. Optical amplifiers do not need to convert the signal to an electrical and back again making them simpler, reliable, and more efficient. They can operate on a wideband basis processing multiple channels at a time.

How does fiber optic networking work?

Modern fiber links are capable of simultaneously transmitting data across multiple channels via a single fiber. This is achieved by using Wavelength-division multiplexing. This technique is analogous to Frequency division multiplexing used in radio carriers but uses light wavelength (measured in nanometers) rather than frequency. Multiple beams of light with varying wavelengths are sent through the fiber, each encoding data on a distinct channel. The network includes a multiplexer within the transmitting equipment and a demultiplexer in the receiving equipment. By using this technique the capacity of fiber networks is multiplied massively.

The wavelengths of light used in fiber networking

Light wavelengths are critical to fiber networks as they determine the maximum distance that data can be transmitted with the least attenuation. Commercial fiber networks will use one of three standard wavelengths for transmission:

  • 850 nm
  • 1300 /1310 nm
  • 1550 nm

These three wavelengths are all in the infra-red portion of the light spectrum. Fiber-optic networking, never uses visible light, always infra-red light because of its desirable behavior in nonlinear media that supports the very fast switching required in networking.

The three key frequencies have been settled upon because they are the infra-red wavelengths that have the lowest levels of attenuation when transmitted through the fiber. They also are less likely to be absorbed or scattered by water, trace metals, and other impurities within the fiber.

  • The 850 and 1300 nm wavelengths are used for multi-mode and LED fiber applications.
  • The 1310 and 1550 nm wavelengths are used for single-mode and laser fiber applications.

Our entire inventory of fiber optic cable, modules, and other components comply with the Restriction of Hazardous Substances (RoHS) Directive and the more stringent REACH requirements that limit the use of hazardous substances like lead or mercury in electrical and electronic equipment. The fiber optic networking equipment also complies with Federal and international conflict mineral legislation that prohibits the use of certain metals that have been procured from sources that are associated with conflict and forced labor.

Frequently asked questions for fiber networking

  • What is a passive optical network?

Passive Optical Networks (PONs)provide broadband network connectivity to multiple end-users. Internet Service Providers (ISPs) increasingly use PONs as access networks for “last-mile” connectivity for their customers. PON has a star or point-to-multipoint topology with each optical fiber serving multiple end-users through the use of passive fiber optic splitters that divides the supplied bandwidth amongst the end-users. They take advantage of wavelength division multiplexing to enable the bi-directional trafficking of data at scale.

    • Optical line terminals are the central hubs of PON networks. At this service provider endpoint, electrical signaling is converted into optical signals. The duplexing performed is also coordinated from this point.

    • Optical network units/terminals are installed close to end-users. They are not access points, but the location in the network where the optical line is terminated and the signal separated into its various components including, voice, TV, and internet.

The IEEE has also standardized Ethernet PON (EPON or GEPON) as part of 802.3ah, released in 2004. This Ethernet standard deals with short-haul networking using a combination of Gigabit Ethernet and fiber optic networking with a single protocol layer. It is inexpensive and has had widespread uptake becoming is the most commonly deployed type of PON network.

  • What is Fiber To The Office?

Fiber to the office, also known as FTTO, uses fiber optic networking to create a local area network (LAN) suitable for an office environment. It is hybrid, combining elements of passive fiber networking and Gigabit Ethernet via specifically designed FTTO switches. The backbone of the network is fiber and distributed from a hub to the office floor. The last 5 meters to the end-user access point is Ethernet.

Fiber To The Desk (FTT) takes fiber connectivity even further. It creates high bandwidth direct fiber connections between the LAN and end-user equipment like laptops or printers. It has proved to be competitively priced, efficacious, and secure especially as it cannot be affected by EMI. End-user equipment can be adapted to access the fiber network via fiber Network Interface Cards, USB to fiber Ethernet adapters, or media converters.

In conclusion

Fiber networking provides robust and reliable connectivity for both indoor and outdoor network installations. High-quality cable and networking components with high intercompatibity and interoperability are key to building fiber and hybrid network solutions that will prove resilient long-term.

CAT 5e Ethernet Cable & Connectors:  Deep Dive

CAT5e is short form for Category 5 enhanced is network cable. The cable supports performance speed of up to 1Gbps and reduces cross-talk interference. It is used for Ethernet (10BASE-T), Fast Ethernet (full duplex 100BASE-TX), and Gigabit Ethernet (1000BASE-T) networks.

Shielding of CAT5e Ethernet cable and RJ45 Connectors: Benefits of Shielded vs Unshielded: A shielded CAT5e Ethernet network cable is more secure from electromagnetic interference (EMI) which can result in partial or complete communication loss. A partial loss makes the user experience a slow connection because of poor data transmission. There is repeated re-sending as the sending equipment is trying to send the correct data hence increasing transfer time.

When the interference is too much, a connection may not be established and loss of signal hence no transmission at all. When using a shielded CAT5e Ethernet network cable, it should be terminated with a shielded RJ45 connector because EMI can affect any part of the cable.

In general, Shielding of cable and RJ45 connectors ensure one gets fast and reliable data transmission compared to unshielded CAT5e Ethernet cable.

CAT5e is terminated with RJ45 connectors.

Category 5E or Cat 5e cable is a type of twisted pair networking cable that is used for making Ethernet network connections. Ethernet cable like Cat 5e forms part of the physical layer (PHY) in the OSI 7-layer model of computer networking. It can be used for data transfer, telecommunications, internet connectivity, and audiovisual applications. Ethernet cable runs with Cat 5e cable can be used to create networks of almost any size and it is known for its ability to support high data throughput and speeds. Its use is specified in the Ethernet standard 803.2 produced by the Institute of Electrical and Electronic Engineers (IEEE), and it also plays a part in wireless networking technologies like WiFi.

This Ethernet cable is a variant of Category 5 Ethernet cable. The “e” in the cable designation stands for “enhanced” as this type of Ethernet cable has differences in its physical and electrical specifications from the standard cable. Cat 5e is backward compatible with Cat 5 cable installations. Both types of Ethernet cable have a bandwidth of 100 MHz.

Category 5e cable is produced in line with several published standards and specifications including:

  • The U.S. standard ANSI/TIA/EIA 568-B.2-1 (2002) is a telecommunications cabling standard for commercial buildings. It specifies Category 5 cables and components for horizontal cable runs in walls, floors, and ceilings as well as patch cabling between devices.
  • International standards such as ISO/IEC 11801 2nd edition (2017) that deal with cabling standards for the general office environment.
  • European standards including EN 50173-1 (2018) outline standards for generic cabling systems in Information Technology.

Twisted pair cables like those in Cat 5e cable, are made from paired wires that are wrapped around each other as a strategy to minimize crosstalk and other electromagnetic interference.

The proximity of the twisted pair wires means that signals traveling through each wire are likely to encounter the same type and magnitude of interference as they travel from the source. This noise rejection strategy makes it easier for interference to be identified and canceled out at the receiving device. Balanced line arrangements like this mean that Ethernet cable is favored for its low signal to noise ratio.

Cat 5e has been the main form of Category 5 cable in use since 2001 and has superseded it to be the primary cable of this category. It is available as patch-cables, crossover cables, and straight-through cables and is connected to punch down blocks or terminated by the RJ45 plug, a type of 8P8C modular connector for making connections via a jack installed in networked devices.

Physical specifications of Category 5e cable

Category 5e horizontal patch cable or work area cable is suitable for all Cat5 applications including 10BASE-T, 100BASE-T, and Gigabit Ethernet.

  • It consists of 4 unshielded twisted pair (UTP) wires, set in a cruciform arrangement. Cat 5e cable also carries a stranded copper drain wire for grounding
  • The center conductor of each wire is made from 7 strands of bare copper wire. It has an American Wire Guage (AWG) of 26.
  • The stranded copper wires are covered in colored polyethylene (PE) jacketing which gives each wire a diameter of 0.95mm (0.037 inches).
  • Each twisted pair is color-coded. This enables the wiring of the cable according to standardized wiring patterns. The four pairs of colors are:
    • The first color code pair has a solid blue wire and a striped blue/white wire.
    • The second color code pair has a solid orange wire and a striped orange/white wire.
    • The third color code pair has a solid green wire and a striped green/white wire.
    • The fourth color code pair has a solid brown wire and a striped brown/white wire.
  • The four twisted-pairs are wrapped in Mylar aluminum polyester film that overlaps the cable core. This shielding faces outwards and has contact with the drain wire.
  • The entire Cat5e cable is wrapped in an outer jacket of PVC. It has an overall diameter of 5.0 millimeters (0.196 inches).

Electrical specifications of Category 5e cable

  • Cat5e cable has a characteristic impedance of 100 Ohms.
  • The maximum frequency of the Cat5e cable is 100 MHz.
  • Its mutual capacitance is 5.6nF/100m
  • The conductor resistance of Category 5e cable is less than 9.80Ω/100m.
  • The velocity of propagation of Cat5e cable is 69%.

Attenuation of Cat 5e cable

At 20 degrees Celsius (68 degrees Fahrenheit):
  • At 1 MHz the attenuation of Category 5e cable is 3.2 dB per 100m.
  • At 4 MHz the attenuation of Category 5e cable is 6 dB per 100m.
  • At 10 MHz the attenuation of Category 5e cable is 9.5 dB per 100m.
  • At 16 MHz the attenuation of Category 5e cable is 12.1 dB per 100m.
  • At 20 MHz the attenuation of Category 5e cable is 13.5 dB per 100m.
  • At 31.25 MHz the attenuation of Category 5e cable is 17.1 dB per 100m.
  • At 62.5 MHz the attenuation of Category 5e cable is 24.8 dB per 100m.
  • At 100 MHz the attenuation of Category 5e cable is 32 dB per 100m.

Mechanical characteristics of Cat5e cable

This cable has an operating temperature range of -20 to +70 degrees Celsius (-4 to 158 degrees Fahrenheit). Its maximum pulling strength is 45 Newtons. The minimum bend radius at installation of Category 5 Ethernet cable is 42 millimeters (1.65 inches).

RJ45 Modular connectors for Category 5e cable
Registered Jack 45 connectors terminate Category 5e cable. These are a type of8 position 8 contact (8P8C) modular connector that is used with twisted pair cables. The eight individual wires of a Cat5e cable are fed into the RJ45 plug and each aligned with their corresponding pin. The RJ45 plug is derived from the analog telephone system standards which specified the connector’s original design. The contemporary RJ 45 specification is outlined in the US standard ANSI/TIA-1096-A and the international standard, ISO-8877.

Category 5e cables that have the connector are mated with the 8P8C modular jacks that are housed within devices. The RJ45 jacks carry sprung metal wires that project away from the connector opening. Insertion of the plus leads to electrical contact between the pins from the plug and the complementary wires in the jack that are opposed under spring tension.

High-quality, RoHS compliant Category 5e cables, and accessories

Our selection of Ethernet cables, connectors, and accessories are made with industry-leading fabrication methods from high-quality materials of good provenance. We ensure that our cables are sourced and manufactured using materials and manufacturing that fully complies with the Restriction of Hazardous Substances (RoHS) Directive, European Union legislation that limits the use of hazardous substances like lead or cadmium in electrical and electronic products (EEE).

The use of Tungsten, Tantalum, Tin, and Gold, known as the 3GT metals is also subject to electronics sector legislation. All Ethernet produces are sold in compliance with key conflict minerals legislation that includes:

  • The Conflict Minerals Regulation (2021)
  • Section 1502 of the Dodd-Frank Act

Why is Category 5e cable important?

Category 5e cable is in widespread use in a variety of networking applications with its operation specified in industry-leading protocols and standards. As a critical physical layer component, this type of Ethernet cable determines the electrical properties, security, and data transfer speeds within Ethernet networks that can exceed 1 Gigabit per second. Key contemporary Cat5e cable applications include:

Category 5e cable for Ethernet over twisted pair

Cat5e cable is routinely used for Ethernet over twisted pair technologies. This superseded the use of coaxial cable for making network connections in the earliest form of Ethernet known as Thick Ethernet or 10BASE5. Thick Ethernet proved inflexible and unwieldy when deployed at scale. Even the use of thinner coax with the development of Thin Ethernet or 10BASE2 has a comparatively reduced scope when compared to the use of twisted pair cabling.

The first use of twisted pair cable for Ethernet was in the 1980s with the introduction of StarLAN, the first iteration of IEEE 802.3. Twisted pair cables were already in use for the analog telephone network, with cable runs in many buildings which greatly reduced deployment costs of the new network once twisted pair cables were established as effective for point to point connectivity.

Twisted pair cabling is now a feature of all Ethernet physical layers. The earlier Ethernet standards only used 2 of the 4 twisted pairs in the cable, but novel applications like Power over Ethernet (PoE) discussed below have found other ways of using the other wires.

Category 5e cable for Fast Ethernet (100BASE-TX)

Fast Ethernet (the copper version) delivers data transfer speeds of up to 100 Mbits per second over Category 5e cable. Introduced in 1995, it was the fastest network of its time. The 803.2u standard specifies data transfer over two sets of twisted pairs (4 wires) within the cable. The active wires (green and orange pairs) are terminated in positions 1, 2, 3, and 6 on modular connector pins and must be wired according to either the T568A or T568B wiring standards. One pair is used for each direction of transfer meaning that Fast Ethernet has a full-duplex operation.

100BASE-TX Ethernet networks are often star networks with participant devices connected to a hub, switch, or controller. The maximum cable length for connections is 100 meters (328 feet). Data for transfer is broken up into frames which carry sources and destination addresses to prevent errors and collisions.

Category 5e cable for Gigabit Ethernet (GbE)

Gigabit Ethernet (1 Gig E) is a version of Ethernet that has speeds of one Gigabit per second. It is outlined in the IEEE standard 802.3ab and overtook Fast Ethernet in the late 1990s due to its significant uplift of speeds. The copper of twisted pair cable version is known as 1000BASET and at a minimum must use Category 5 Ethernet cable. Network segment cable lengths for Gigabit Ethernet are limited to 100 meters (328 feet).

1000BASET uses all four twisted pairs in CAT5e cable with simultaneous bi-directional transmissions.

Gigabit Ethernet also uses autonegotiaton. This is a physical layer signaling mechanism that involves connected devices synchronizing their transmission parameters (speed) for the best-optimized performance that can be achieved by both.

Category 5e cable for Audio over Ethernet (AoE

Category 5e cables are also cable of supporting real-time digital audio transmissions and is actively installed in public auditoria and other facilities that require XLR mic level signal coverage or high-quality audio broadcasting. In these applications, Cat5e cable is advantageous as it is designed for long-term installation and routing in public and commercial spaces, and may already have been installed as part of a home network.

The quality and speed of audio transmission are superior to VoIP and AoE has higher fidelity, bitrates, and extremely low latency which makes it advantageous for professional audio. Like standard Ethernet, the digital audio is transferred directly in frames.

There are several open-source and proprietary standards that provide detailed specifications for Audio over Ethernet networks. Most will use Category 5 cable and 1000BASE-TX signaling. Notable Layer 1 protocols for AoE over Cat5e include:

  • Behringers ULTRANET
  • SuperMAC
  • HyperMAC
  • AudioRail

Cat5e cable can also be used as speaker wire or routing for home theater, with some manufacturers even offering RJ45 jacks on speakers.

Category 5e cable for HDBaseT

HDBaseT is a proprietary set of standards for the transfer of audiovisual data over Ethernet cables that are Category 5 and above and terminated by a modular connector like RJ45. It has made the following functionalities available over Cat 5 Ethernet cable:

  • uncompressed ultra-high-definition video over Ethernet
  • digital audio
  • DC power
  • USB 2.0

The standards have been developed by HDBaseT Alliance which includes companies like Samsung, Sony, and LG Electronics as founding members. The first (1.0) specification that was released in 2010 provided a novel solution for home multimedia connectivity. 2019 saw the release of a 3.0 specification which increased the downstream bandwidth available to support the transmission of uncompressed 4K video. Using Ethernet over twisted pair, HDBaseT can also be used for internet access or SmartTV with compatible devices. Up to 7 USB devices can be simultaneously supported using this connectivity protocol. HDBaseT has extremely low latency and transmissions can take place over cable lengths of up to 100 meters (328 feet).

Category 5e cable for Power over Ethernet (PoE)

Power over Ethernet is used to describe a heterogeneous group of standards and protocols that enables DC power to be transferred to devices over twisted pair Ethernet cables like Cate 5e.

Apart from cable the other key components in PoE networks are:

  • Power Sourcing Equipment (PSE) are the devices that provide source power to devices via connected Category 5 Ethernet cable. Network switches (endspan devices) and PoE injectors (midspan devices) are capable of providing power in this way.
  • Powered Devices (PD) receive power via Ethernet cables. Depending on the device application, it may also have integrated backup or auxiliary power.

PoE means that a single Category 5e cable can not only transmit data but also the power to devices including closed-circuit television cameras, VoIP phones, and wireless access points. PoE typically uses two of the 4 signal pairs in Category 5 cable for power transfer with positive voltage transmitted on wires 4 and 5 and negative voltage on wires 7 and 8. Other protocols are capable of transferring power on the same wires that are used for data (Alternative A PoE) and may use all four pairs within a cable (known as 4-pair transmission or 4PPoE).

The IEEE Ethernet protocol 802.3 specifies at least 3 forms of PoE:

  1. 802.3af This original PoE standard, released in 2003, delivers 15.4 Watts of DC power with a minimum voltage of 44 V DC and 350 mA. As some of the transmitted power dissipates in the cable, a wattage of 12.9 Wattage is reliably provided.
  2. 802.3at The 2009 PoE standard known as PoE+, 25.5 Watts of DC power for suitable devices.
  3. 802.3bu was released in 2016 and introduced single-pair power over data lines. This standard was developed for automotive and industrial applications with 10 power classes ranging from 0.5 to 50 Watts.

Frequently asked questions

  • Can Cat 5e cables be used for 2.5GBASE-T or 5GBASE-T Ethernet?

2.5GBASE-T and 5BASE-T deliver Ethernet at speeds of either 2.5 or 5 Gbit per minute as specified in IEEE 802.3bz. They have been developed as a response to demand for faster Ethernet speeds that are comparable to those attained with WiFi. 2.5 Gigabit Ethernet can use existing Gigabit Ethernet infrastructure and can be run reliably over up to 100 meters (328 feet) of Category 5e cable. However, Category 5e cable is not suitable for supporting 5 Gigabit Ethernet, this requires Category 6 cable.

  • Why are category 5e Ethernet cable runs limited to 100 meters (328 feet) in length?

The specified length of Ethernet cables like Cat5e in the leading protocols is limited because of the effects of signal attenuation. When a signal is transmitted along a length of cable, some of the electromagnetic energy transmitted from the source will be dissipated or absorbed by the cable’s environment before it reaches its destination. This reduction in signal is measured as a ratio between the input and output signal strength in decibels per foot or meter of cable length. As the length of the cable increases, the level of attenuation increases. Beyond 100 meters, the performance of the cable may become deranged from its specification.

  • Can a category 5e cable be used to share internet from a PC?

A PC with a wired or wireless internet connection can share its connectivity with another computer directly via an Ethernet cable via suitable jacks on both devices. Simply connect the Category 5e cable from the host PC to the client device. If either device lacks an Ethernet port, a USB/Ethernet adapter can be used. Once the computers are physically connected the network settings of the host computer will need to be reconfigured to allow the client device to use your network.

  • Can CAT 5e cable be installed outdoors?

Ethernet cable can be installed outside and is often used to provide network connectivity between properties. The type of Ethernet cable used for outdoor installations needs to be able to resist the degrading effects of exposure to dirt and dust, moisture, temperature extremes, and solar radiation. Standard Ethernet cable is not suitable as it will quickly degrade, leading to deteriorated network performance and costly downtime. An outdoor Ethernet cable will have the following features that prolong its lifespan and performance in an outside setting:

    • Solid copper wire
    • Rugged weatherproof high-density polyethylene (HDPE) jacketing
    • UV stabilized plastic jacketing

This often makes outdoor Cat5e cable thicker and less flexible than its standard counterpart. The cable connections can also be housed within weatherproof RJ45 glands and jacks which seal the mated connection from ingress of dust and moisture.

Ethernet Cables & Fiber

Ethernet Cables & Fiber

Differences among CAT5e, CAT6, CAT6A, CAT7, CAT8 Ethernet cable

Ethernet cables physically connect local area networks via eight internally twisted and shielded wires. The wires come in either solid or stranded configurations. Solid wires deliver better performance but are more fragile and prone to break.

Understanding the categories of Ethernet cabling is crucial to selecting the right one for your networking needs.

Twisted-pair Ethernet cables have progressively improved performance over consecutive generations. Tighter winding, complex sheathing, and shielding have resulted in the advancement of Ethernet cable categories. Here is a summary of the different categories of Ethernet cables.

CAT 5e

  • CAT5e is Enhanced CAT 5 and is an improvement to the standard CAT 5. CAT 5e is a Class D cable operating at a data transmission bandwidth frequency of up to 100 MHz and a 1000Mbps data transfer rate with a maximum range of 100 meters. CAT 5e can ideally be used for 1Gbit applications.
  • CAT 5e has completely replaced its predecessor, CAT 5. It is preferred in home and office networks with moderate data transfers between 10-100 meters due to its flexibility, low cost, ease of crimping and Gigabit Ethernet capability.

CAT 6

  • CAT 6 is a Class E cable. Supports data transfer rates of up to 10Gbps at a peak bandwidth frequency of 250 MHz. CAT 6 is certified for a maximum range of 100 meters, though due to crosstalk at 10Gbps it is reliably used for a maximum of 55 meters’ transmissions.
  • CAT 6 is more tightly wound than CAT 5e at more than 2 twists/cm, featuring a tougher outer sheath and central pair separator spine to reduce Alien and near crosstalk, and increase rigidity.

    CAT 6 lies in a grey area between the cost-effectiveness of CAT 5e at Gigabit speed and the significant performance improvement of CAT 6A.

CAT 6A

  • The A stands for “Augmented.” CAT 6A cables support 10Gbps data transfers at 500 MHz - twice the frequency of CAT 6 and supports 10Gbps speeds to 100 meters. The cable has a thicker sheath then CAT 6, reducing crosstalk and increasing SNR at high data speeds. The CAT 6A is a Class Ea cable owing to the thick sheath and even stiffer pair separator spine reducing its flexibility.
  • Due to its low flexibility and tough sheath, CAT 6A cables are generally used for industrial applications, outdoor and large-scale networks requiring high data transfers over long distances.

CAT 7

  • CAT 7 is a stiff Class F cable, with separate twisted pair shielding and additional overall outer shielding beneath a tough outer Sheath. Tests have shown that CAT 7 can transmit at a 600 MHz bandwidth frequency, 10Gbps to 100 meters, 40Gbps to 50 meters and 100Gbps to 15 meters.
  • Shielding on the CAT 7 cable needs to be grounded especially at high transfer speeds. It requires GigaGate45 connectors, and modern infrastructure to realize the full speed. CAT 7A is also available, sharing most features with CAT 7, but able to transmit at 1 GHz bandwidth frequency.

    CAT 7 is almost exclusively used in data centers and lager high-throughput network.

CAT 8

  • CAT 8 is a heavily shielded Class II cable that is yet to hit mainstream after extensive testing and standardization. CAT 8 can support bandwidths of up to 2 GHz, and manage a data transfer rate of 25Gbps and 40Gbps on a maximum cable length of 30 meters.
  • CAT 8 is intended for use in high-performance server rooms and data centers.

Ethernet Cables for Local Area Networks

Ethernet cables are a type of networking cable that are used to connect electronic devices. They are widely used to create wired networks of varying sizes, specifications, and complexity. When they are terminated with their complementary Ethernet connector and Ethernet ports. Ethernet cables are capable of supporting data transfer of varying speed and throughput. Computers and other hardwired networked devices use Ethernet cables to securely share files and communicate efficiently. They are one of the early building blocks or media specified in the Physical Layer (PHY) of many well-known network protocols as well as a key component in providing internet connectivity.

Quality RoHS compatible Ethernet cables and connectors. Our extensive range of Ethernet cables, connectors, and other accessories are manufactured to the highest standards for consistent, reliable performance. All materials and fabrication techniques used are fully compliant with the following legislation:

What is Ethernet?

Ethernet is a wired networking technology that is used to devise and build a range of local area networks (LANs) and wide-area networks (WANs). It is also capable of supporting metropolitan area networking (MAN), amenity-like expansive networking that connects and serves computers in large numbers and on a scale equivalent to a geographic metropolitan area. It is used in almost every sector of the industry as well as domestic and consumer computing. It also integrates well with WiFi as it is capable of the internetworking necessary for supporting the Internet Protocol.

Ethernet provides physical-space connectivity between computers and devices. The networks created can support a high number of nodes securely and over long distances. It was first standardized in the 1980s with the release of the 802.3 protocol by the Institute of Electrical and Electronics Engineers (IEEE). Since its introduction, it has been further revised and refined with an increase in bit rates, security, and a broadening of its applications while remaining largely backward compatible. Contemporary bit rates can exceed 400 Gbit per second. The standardization of Ethernet has also defined the physical space with all compatible hardware carrying the same standardized ports.

How does Ethernet work?

Ethernet data transfer works by breaking down the data into smaller units known as frames. Each frame carries identifying addresses for the data source and destination. The frames also have an error-checking component that can eliminate damaged frames and trigger their re-transmission.

Ethernet structure and functionality span Layers 1 and 2 of the seven-layer Open Systems Interconnection model (OSI model) for telecommunication and computing systems. This means that it is concerned with the transfer of data between participant nodes in a network via its physical layer which includes Ethernet cables.

Every piece of Ethernet hardware and components has a unique identifier (assigned by the manufacturer) which serves to identify them and be used as a network address. This burned-in address, known as a Media Access Control (MAC) address consists of 6 sets of hexadecimal digits usually separated by hyphens.

The MAC address is used to transfer data frames between nodes correctly. The MAC sublayer oversees which address is allowed to see the transferred frames using collision avoidance protocols.

Ethernet cables are twisted-pair cables

Ethernet was initially developed using coaxial cables rather than the recognizable twisted pair cable that is now in widespread use. 10Base5 Ethernet or thicknet was expensive and difficult to install and maintain, often due to the inflexibility of the coax used.

Contemporary Ethernet cable uses twisted pair cabling. This cable type was invented by Alexander Graham Bell and is made up of paired conducting wires that are twisted together to reduce electromagnetic leakage, noise, and cross-talk.

A twisted-pair Ethernet cable consists of 8 wires that are color-coded and arranged in 4 twisted-pairs. Their color and arrangement are important for terminating Ethernet cables with 8-position modular connectors, like the RJ45 connector.

Twisted pairs are used to create balanced lines which are transmission lines made up of two conductors of the same type and impedance. Because of their proximity, the paired wires will be subjected to the same type and level of EM interference as signals pass along them from the source and will be far easier to cancel out at the receiving end (common mode rejection). Balanced circuits that use these lines are efficient at rejecting electromagnetic interference and are capable of faster and more precise data transfer. If the pairing fails or the system is unbalanced in any way, common-mode rejection fails and the system becomes vulnerable to interference.

The wires may be shielded twisted pair (STP) or unshielded twisted pair (UTP). Shielded or screened wires have foil or braided shielding that is conductive and adds additional protection against electromagnetic interference. The choice of cable may be specified by a networking protocol to achieve specific speeds and performance or selected according to the level of shielding an application requires. The shielding of the cable contributes to its categorization as outlined for each cable type below. The key shielding types are:

  • Individual shield (U/FTP)

These twisted pairs or quads have individual aluminum foil shielding. They are also known as “shielded twisted pairs” or “pair in metal foil.” They are effective in preventing leakage of electromagnetic energy and crosstalk.

  • Overall shield (F/UTP, S/UTP, and SF/UTP)

This type of shielding also known as shielded twisted pair, foiled twisted pair, or screened twisted pair, covers all of the unshielded pairs within an Ethernet cable with foil, braided shield, or a combination of both.

  • Individual and overall shield (F/FTP, S/FTP, and SF/FTP)

With this type of twisted pair cable, there is not only foiled shielding of individual wires within the pairs, but also an overall outer foil or braided shield. It is also known as screened foiled twisted pair, or fully shielded twisted pair. This type of Ethernet twisted pair cable is highly insulated against electromagnetic interference.

  • The twist rate of twisted pairs

Twisted pairs have a specified pitch or rate of twisting, measured in twists per meter. This helps to determine the arrangement of the pairs within an Ethernet cable. The pairs that make up a cable must have different twist rates to preserve the benefits of twisting. Adjacent twisted pairs with a like pitch are avoided.

  • The twisted pairs within an Ethernet cable are color-coded

A color-coding system is used to identify the individual conducting wires that make up an Ethernet cable. The insulating plastic jacket that surrounds the wires carries the colors, which also guide the wiring of these cables following various standards and specifications.

There are up to 25 different color combinations. Each twisted pair is made up of a major color and minor color which are selected from two different groups. The major colors include white, red, black, yellow, and violet and the secondary colors include blue, orange, green, brown, and slate. The major wire carries a solid block color, and the minor wire in the pair is white with colored stripes or rings.

Types of Ethernet cables

There are 8 types of Ethernet cables with the earlier Ethernet cable types being used for telephone wiring, ISDN, and token ring. The most widely used types of Ethernet cables are Category 5e and 6 cables and their variants which we describe below.

Category 6 Ethernet cable

Cat 6 Ethernet cable is a twisted pair cable that has become an industry standard. It is manufactured to deliver consistent performance at frequencies of up to 250 MHz. It was devised as an improvement on the existing CAT5 cable to improve data speeds. It is backward compatible with Category 5 and 5e (Cat 5e) cable. It is widely used in network physical layers for computing as well as audiovisual and telco applications. Category 6 cable has greater shielding and protection against unwanted noise and crosstalk. Its physical and electrical characteristics are outlined in several specifications including:

  • ISO/IEC 11801 global cabling standard has been extended to publish specifications for Category 6A cable which works with newer connecting hardware for enhanced performance.
  • ANSI/TIA-568.2-D is a standard produced by the Copper Cabling Subcommittee of the Telecommunications Industry Association (TIA). This standard specifies the transmission and mechanical requirements for category 6 cable and its variants.

The performance of Category 6 cable means that it can be used for higher speeds of Ethernet including Gigabit Ethernet. It is suitable for supporting 10 Base-T, 100 Base-T, 1000 Base-T, and 10G Base-T.

Category 6 cable physical specifications
Cat6 UTP horizontal cable uses several strategies to improve its performance at higher frequencies and support speeds of up to 1000 Mbits per second over long runs. They are most notably:

  • Thicker wire
  • More shielding
  • The greater pitch of the twisted pairs

Category 6 cable consists of 4 twisted pairs laid up in a cross arrangement. The center wires of the twisted pairs are solid, plain copper wire with an AWG of 23. The conductor diameter is 0.57 millimeters (0.022 inches).
The copper wire is insulated with high-density polyethylene (HDPE) jacketing for an outer diameter of 1.1 millimeters (0.043 inches). The drain wire carried by this cable is 0.4 millimeters (0.0157) of tinned copper. The twisted pairs are covered by an aluminum foil screen and PVC jacketing for an overall diameter of 7.3 millimeters (0.287) inches.

CAT5 FTP cable has a temperature range is -10 to +60 degrees Celsius (-14 to 140 degrees Fahrenheit). It has a minimum bend radius for installation of 40mm (1.57 inches). It has a bend radius of 25 millimeters (1 inch).

The color-coding of the four twisted pairs in Category 5 Ethernet cable is as follows:

  • Pair 1 Blue / Striped Blue
  • Pair 2 Orange / Striped Orange
  • Pair 3 Green / Striped Green
  • Pair 4 Brown / Striped Brown

Category 5 cable electrical specifications

  • Category 5 Ethernet cable is rated for frequencies up to 250 MHz.
  • It is known for its high signal to noise ratio (SNR), due to the use of balanced lines.
  • Its impedance is 85 to 115 Ohms. depending on the frequency at which it is used.
  • The velocity of propagation of category 6 cable is 68 percent.
  • At 250 MHz, the attenuation of Cat5 cable is 3.1 dB/10m.
[D] Category 6A Ethernet cable

This variant of Category 6 cable is labeled A for Augmented with standards for its specifications and performance updated as recently as 2008. It is also known as Category 6E Ethernet cable. It is a shielded Ethernet cable with a bandwidth frequency of 500 MHz, twice that of the standard Cat6 cable. Cat6a cable has proven advantageous for supporting higher transmission speeds (10,000 Mbits per second / 10 Gigabits per second) over longer lengths of cable. The careful shielding almost completely screens out electromagnetic interference and crosstalk, but also means that this form of Ethernet cable is less flexible.

Why are Ethernet cables important?

Ethernet cables for 802.3 networking

Ethernet network cables carry Ethernet and the performance of the different cable types needs to be precisely matched to the type of Ethernet being deployed. As the IEEE 802.3 standard has been developed and expanded, newer forms of Ethernet over twisted pair or classic Ethernet have emerged that are capable of faster speeds and less error-prone performance. These types of Fast Ethernet and Gigabit Ethernet include:

  • What is 100BASE-T?

This form of Ethernet was introduced in the mid-1990s as the 802.3u standard and requires cables that are Category 5 and above. The networks built using this form of Fast Ethernet are star networks centered around a central hub. The shared media local area networks (LANs) created with Fast Ethernet are comprised of segments that can have cables of up to 100 meters (328 feet) in length. Connections are duplex, with twisted pairs are used separately to serve each direction with bidirectional data throughput of 100 Mbit per second.

  • What is 1000BASE-T?

1000Base-T is Gigabit Ethernet. This form of internet is capable of data transfer at a rate of 1 Gigabit per second. It is specified by the 802.3b standard which superseded Fast Ethernet in 1999. It has largely replaced Fast Ethernet for LAN networking due to its speed and innovations in hardware and cables. Category 5, Category 5e, and Category 6 cables can support Gigabit Ethernet with cable runs of up to 100 meters in length performing optimally. 1000BASE-T uses all four twisted pairs within the cable for simultaneous bidirectional data transmissions. This Ethernet version is used for broadband applications and data centers.

  • What is 10GBASE-T?

Category 6 cable and above is capable of supporting 10 Gigabit Ethernet which has a data rate that is ten times the Gigabit Ethernet level. It also can use fiber-optic cable, but copper is cheaper and massively impacts installation costs. It was first introduced in 2002 as IEEE 802.3ae. 10 Gigabit Ethernet has taken time to become widely adopted due to hardware costs (particularly the ports). It delivers Ethernet frames across full-duplex point-to-point links with lower latency, and over cable lengths of up to 100 meters (328 feet). It is also fully backward compatible with standard Gigabit Ethernet.

Ethernet cables are compatible with a range of key network components.

What is an Ethernet connector?
The RJ45 or Registered Jack 45 connector is the standard connector for terminating Ethernet cables. They have a familiar appearance that is much like a larger analog telephone plug. The connector design and specification were initially developed in the late 1970s in accordance with telecommunications specifications.

The male plug that is used to terminate Ethernet cables has a row of 8 metal pins that retain the twisted pair wires from the cable. Within the connector, the 4 twisted pairs have an 8 Position, 8 Contact (8P8C) configuration. RJ45 connectors have to be carefully wired as if the ordering of the wires is incorrect, the cable will not function. For bidirectional data trafficking, the wires are divided into transmit and receive wires. The ordering of the wires is specified by the wiring codes T-568A and T-568B, which can also be used to classify cable. They differ only in the arrangement of the orange twisted pair wires. Both color patterns are recognized by the ANSI/TIA-568-C standard but Federal cabling undertaken for the US Government requires only T-568A wiring.

What are Ethernet switches?
These network switches or hubs are used in computer networking for receiving and forwarding the data packets or frames that are transferred within a network. Ethernet switches are the most common type of network It is a unit that contains multiple ports and relies on MAC addresses for correctly forwarding the data, only forwarding to the port that is connected to the recipient device.

What is an Ethernet router?
Routers are electronic devices that are also able to send and forward information in computer networks. Ethernet ports are a common port on routers, which allow a single IP address to be shared among several network devices. They are a key interface between wired and wireless networking and connectivity as a router can send and receive data via Ethernet cables and broadcast the data (or access the internet) wirelessly via WiFi.

Frequently asked questions

  • How do you wire an Ethernet connector?

To correctly terminate an Ethernet patch cable you will require a suitable length of Category 5 or 6 cable and RJ45 connectors as well as wire cutters for cutting and stripping the cable, and an RJ45 Modular Connector Crimper.

  1. The Ethernet cable must first be prepared by cutting it to length and stripping off 2 inches of the cable sheath.
  2. The twisted pairs within the cable should be spread out according to the wiring pattern that is required.
  3. The individual wires should be trimmed to an equal length and stripped of their polyethylene insulation leaving between ½ and ¾ of an inch (12 to 19 millimeters) of copper conducting wire exposed.
  4. The exposed wires should be inserted in order into the front of the RJ45 plus. The sheath of the Ethernet cable should follow by about ½ inch (12 millimeters).
  5. The connector can now be crimped with the RJ45 crimping tool. The wires are held down by pins and the cable sheath is also crimped for a secure hold.
  • What is a straight-through Ethernet cable?

A straight-through Ethernet cable is one that is used to connect a computer to an Ethernet switch, hub, or router. Straight-through cables connect devices of different types.

  • What is a patch Ethernet cable?

Patch cables are used to patch in or connect one device to another for routing a signal. It is now widely used as a generic term to describe Ethernet cables.

  • What is a crossover Ethernet cable?

Crossover cables are used to connect computers directly. They are used to create Ethernet connections between like devices.

  • Does Ethernet cable length matter?

Like other forms of cable, Ethernet is subject to signal loss along its length. This is known as attenuation and varies between cable types and manufacturers. Ethernet cable runs are normally limited to 100 meters (328 feet) as beyond this length attenuation becomes significant and will impact network performance.

  • ptical fiber is a high-clarity fully transparent fiber made from strands of glass or certain plastics that have been drawn out to be as thin as human hair. Like radio frequency signal transmission down a copper wire, fiber networking uses light as its carrier wave, using a range of modulation techniques to encode and transmit data. Unlike radio frequency connectivity, fiber-optic networking is immune to electromagnetic interference. Fiber has demonstrable efficacy for supporting secure,high-speed, high-bandwidth connectivity over significant distances with minimal signal loss.

Fiber is capable of transferring a variety of data including voice, video, audio, and IP data packets. Current applications of this technology include telecommunications, broadband internet connectivity, and cable television

The history of fiber networks.

The development of fiber optic technology spans over 50 years and can be traced back to the invention of the laser. Before that Alexander Graham Bell created a device, named the photophone that could transmit sound on a beam of light. The use of optical fiber for communications was first proposed in the mid-1960s with the suggestion that the photons of light could be guided and directed in a similar way to electrons in a copper cable.

Early fiber optic technology was affected by high levels of losses from the prototype optical fibers and progress was only made in the 1970s where methods were found to drastically reduce losses, making fiber optics viable for its first, experimental network deployments from 1975.

Progress in fiber optic networking proceeded on a step-wise basis to its present levels of efficacy and performance. The bit rate (B) and repeater spacing (L) for these networks increased greatly, leveling off to where it is today.

  1. First-generation fiber-optic networks used multimode fiber and operated at 850 nm using a Gallium Arsenide (GaAs) semiconductor laser. These networking components were commercially released in the early 1980s and supported speeds of up to 45 Mbit/s with repeater spacing of up to 10 kilometers (6.21 miles), far greater than comparable coax systems at that time.

  1. Second-generation fiber-optic networks or lightwave systems were capable of achieving bit rates of up to 1.7 Gbit/s with an uplift to repeater length of 50 kilometers (31 miles). Both first and second generations systems were specified by the International Telecommunications Union (ITU), with the second-gen network operating at 300nm in single mode.

  1. Third-generation fiber-optic networks were limited by significant losses due to increasing repeater spacing at 300 nm. But by 1992, single-mode systems were commercially available that operated at 2.5 Gbit/s reliably and up to 10 Gbit/s in experimental settings. Third-gen optical systems were able to operate at 550 nm. Repeaters to forward the transmitted signals needed to be installed every 70 to 80 kilometers. Further developments in the technology introduced fiber amplifiers (in 1989) that can boost repeater spacing. Also, Wavelength Division Multiplexing (WDM) was capable of boosting the bit rate that could be achieved. These enhancements converged with the emergency of fourth-generation lightwave systems.

  1. Fourth-generation fiber-optic networks use amplifiers and multiplexing to boost speeds above 5 Gbit/s and repeater distances in the hundreds of kilometers.

  1. Fifth-generation or fifth-phase fiber-optic networks include the contemporary forms of fiber networking which have developed in a variety of directions including long-haul, high-capacity, multimode, optical/electrical/optical (O/E/O), and multi-channel networking. Also, extremely low-loss fibers have been developed such as the dry or low water peak fiber. Contemporary lightwave systems have tens of channels with end-user networking speeds of tens of Gigabits per second. Network topography has also matured with the development of optical transport networks (OTNs). The ITU has released successive standards for OTNs that have supported a transition in fiber technology from short distance links to long-distance backbone links over optical paths of 2000 kilometers.

Key fiber network components

[A] Optical transmitters: Optical transmitters receive an electrical input and convert it into an optical signal that is transmitted down the fiber cable. These transmitters are LED or laser diode semiconductor devices that are capable of operating at the required wavelength with high-frequency modulation. Ideally, the transmitters are small and compact and integrate both the electrical and optical connectors.

  • Laser diodes that produce coherent light (light with a fixed phase wave) are highly efficient, with little loss. They produce a directional output with effective coupling to the attached fiber cable. Vertical Cavity Surface Emitting Laser (VCSEL) devices have enhanced speed, power, and spectral performance compared to LED devices. Modulation is achieved by the current that is directly applied to the transmitter.

  • Gallium Arsenide LED optical transmitters are cheaper and produce incoherent light, which has a wider and more variable spectral width. They are less efficient than their laser counterparts with only a small proportion of the input power converted into launched power via the fiber cable.

[B] Optical receivers are devices that are able to receive an optical signal via a fiber connection and convert it into an electrical output signal. These devices used the photoelectric effect, where electron emissions are generated by transmitted light hitting diode material within the receiver.

The optical-electrical converter portion of the receiver is coupled to transimpedance and limiting amplifiers that assist in producing a viable digital output signal as it can become attenuated by the conversion process. Other signal processing steps may also be applied to the signal recovered by these devices depending on where the transmitted light was coherent or incoherent.

[C] Optical fiber cable is comprised of flexible thin, glass, or plastic fibers that are bundled and clad to guide light that is transmitted down them. The cables use total internal reflection fast, directional transmission. A typical fiber cable is comprised of a core of fibers, that are clad in low refractive material and sealed in a protective outer jacket known as a buffer.

Despite being made up of hair-like glass fibers these cables are resilient and can be routed, buried, or submerged similarly to copper cable. Once installed their maintenance requirements are low.

There are two key classes of optical fiber used in networking.

  1. Multi-mode optical fiber cable has a core that has a larger diameter (50 micrometers) meaning that it can operate effectively with LED optical transmitters that use incoherent light and have poorer precision. Because of the equipment used with it, multi-mode fiber can be affected by distortion and attenuation, which limits the bandwidth of links formed with this cable.

  2. Single-mode optical fiber has a diameter of fewer than 10 micrometers but requires precision network components for more accurate data transmission and more robust, longer-distance links.

Like coax, both types of fiber are available in a range of grades depending on the wavelength of light they use and their attenuation. The quality of the fiber (particularly the presence of water and other impurities) and its bend radius are key determinants of the performance of the cable and its level of attenuation.

[D] Amplifiers: As mentioned in the history of Fiber networking above, distortion and attention of transmitted signals were originally key limiters of the utility of fiber. An initial solution for this problem was the use of optoelectronic repeaters that would receive and retransmit the optical signal at regular intervals. These devices would have to be installed at regular intervals (every 20 kilometers / 12 miles) along a cable run which proved expensive.

Repeaters have been largely superseded by amplifiers that do not need to convert the signal to an electrical one before enhancing it and sending it on. Optical amplifiers do not need to convert the signal to an electrical and back again making them simpler, reliable, and more efficient. They can operate on a wideband basis processing multiple channels at a time.

How does fiber optic networking work?

Modern fiber links are capable of simultaneously transmitting data across multiple channels via a single fiber. This is achieved by using Wavelength-division multiplexing. This technique is analogous to Frequency division multiplexing used in radio carriers but uses light wavelength (measured in nanometers) rather than frequency. Multiple beams of light with varying wavelengths are sent through the fiber, each encoding data on a distinct channel. The network includes a multiplexer within the transmitting equipment and a demultiplexer in the receiving equipment. By using this technique the capacity of fiber networks is multiplied massively.

The wavelengths of light used in fiber networking

Light wavelengths are critical to fiber networks as they determine the maximum distance that data can be transmitted with the least attenuation. Commercial fiber networks will use one of three standard wavelengths for transmission:

  • 850 nm
  • 1300 /1310 nm
  • 1550 nm

These three wavelengths are all in the infra-red portion of the light spectrum. Fiber-optic networking, never uses visible light, always infra-red light because of its desirable behavior in nonlinear media that supports the very fast switching required in networking.

The three key frequencies have been settled upon because they are the infra-red wavelengths that have the lowest levels of attenuation when transmitted through the fiber. They also are less likely to be absorbed or scattered by water, trace metals, and other impurities within the fiber.

  • The 850 and 1300 nm wavelengths are used for multi-mode and LED fiber applications.
  • The 1310 and 1550 nm wavelengths are used for single-mode and laser fiber applications.

Our entire inventory of fiber optic cable, modules, and other components comply with the Restriction of Hazardous Substances (RoHS) Directive and the more stringent REACH requirements that limit the use of hazardous substances like lead or mercury in electrical and electronic equipment. The fiber optic networking equipment also complies with Federal and international conflict mineral legislation that prohibits the use of certain metals that have been procured from sources that are associated with conflict and forced labor.

Frequently asked questions for fiber networking

  • What is a passive optical network?

Passive Optical Networks (PONs)provide broadband network connectivity to multiple end-users. Internet Service Providers (ISPs) increasingly use PONs as access networks for “last-mile” connectivity for their customers. PON has a star or point-to-multipoint topology with each optical fiber serving multiple end-users through the use of passive fiber optic splitters that divides the supplied bandwidth amongst the end-users. They take advantage of wavelength division multiplexing to enable the bi-directional trafficking of data at scale.

    • Optical line terminals are the central hubs of PON networks. At this service provider endpoint, electrical signaling is converted into optical signals. The duplexing performed is also coordinated from this point.

    • Optical network units/terminals are installed close to end-users. They are not access points, but the location in the network where the optical line is terminated and the signal separated into its various components including, voice, TV, and internet.

The IEEE has also standardized Ethernet PON (EPON or GEPON) as part of 802.3ah, released in 2004. This Ethernet standard deals with short-haul networking using a combination of Gigabit Ethernet and fiber optic networking with a single protocol layer. It is inexpensive and has had widespread uptake becoming is the most commonly deployed type of PON network.

  • What is Fiber To The Office?

Fiber to the office, also known as FTTO, uses fiber optic networking to create a local area network (LAN) suitable for an office environment. It is hybrid, combining elements of passive fiber networking and Gigabit Ethernet via specifically designed FTTO switches. The backbone of the network is fiber and distributed from a hub to the office floor. The last 5 meters to the end-user access point is Ethernet.

Fiber To The Desk (FTT) takes fiber connectivity even further. It creates high bandwidth direct fiber connections between the LAN and end-user equipment like laptops or printers. It has proved to be competitively priced, efficacious, and secure especially as it cannot be affected by EMI. End-user equipment can be adapted to access the fiber network via fiber Network Interface Cards, USB to fiber Ethernet adapters, or media converters.

In conclusion

Fiber networking provides robust and reliable connectivity for both indoor and outdoor network installations. High-quality cable and networking components with high intercompatibity and interoperability are key to building fiber and hybrid network solutions that will prove resilient long-term.

CAT 5e Ethernet Cable & Connectors:  Deep Dive

CAT5e is short form for Category 5 enhanced is network cable. The cable supports performance speed of up to 1Gbps and reduces cross-talk interference. It is used for Ethernet (10BASE-T), Fast Ethernet (full duplex 100BASE-TX), and Gigabit Ethernet (1000BASE-T) networks.

Shielding of CAT5e Ethernet cable and RJ45 Connectors: Benefits of Shielded vs Unshielded: A shielded CAT5e Ethernet network cable is more secure from electromagnetic interference (EMI) which can result in partial or complete communication loss. A partial loss makes the user experience a slow connection because of poor data transmission. There is repeated re-sending as the sending equipment is trying to send the correct data hence increasing transfer time.

When the interference is too much, a connection may not be established and loss of signal hence no transmission at all. When using a shielded CAT5e Ethernet network cable, it should be terminated with a shielded RJ45 connector because EMI can affect any part of the cable.

In general, Shielding of cable and RJ45 connectors ensure one gets fast and reliable data transmission compared to unshielded CAT5e Ethernet cable.

CAT5e is terminated with RJ45 connectors.

Category 5E or Cat 5e cable is a type of twisted pair networking cable that is used for making Ethernet network connections. Ethernet cable like Cat 5e forms part of the physical layer (PHY) in the OSI 7-layer model of computer networking. It can be used for data transfer, telecommunications, internet connectivity, and audiovisual applications. Ethernet cable runs with Cat 5e cable can be used to create networks of almost any size and it is known for its ability to support high data throughput and speeds. Its use is specified in the Ethernet standard 803.2 produced by the Institute of Electrical and Electronic Engineers (IEEE), and it also plays a part in wireless networking technologies like WiFi.

This Ethernet cable is a variant of Category 5 Ethernet cable. The “e” in the cable designation stands for “enhanced” as this type of Ethernet cable has differences in its physical and electrical specifications from the standard cable. Cat 5e is backward compatible with Cat 5 cable installations. Both types of Ethernet cable have a bandwidth of 100 MHz.

Category 5e cable is produced in line with several published standards and specifications including:

  • The U.S. standard ANSI/TIA/EIA 568-B.2-1 (2002) is a telecommunications cabling standard for commercial buildings. It specifies Category 5 cables and components for horizontal cable runs in walls, floors, and ceilings as well as patch cabling between devices.
  • International standards such as ISO/IEC 11801 2nd edition (2017) that deal with cabling standards for the general office environment.
  • European standards including EN 50173-1 (2018) outline standards for generic cabling systems in Information Technology.

Twisted pair cables like those in Cat 5e cable, are made from paired wires that are wrapped around each other as a strategy to minimize crosstalk and other electromagnetic interference.

The proximity of the twisted pair wires means that signals traveling through each wire are likely to encounter the same type and magnitude of interference as they travel from the source. This noise rejection strategy makes it easier for interference to be identified and canceled out at the receiving device. Balanced line arrangements like this mean that Ethernet cable is favored for its low signal to noise ratio.

Cat 5e has been the main form of Category 5 cable in use since 2001 and has superseded it to be the primary cable of this category. It is available as patch-cables, crossover cables, and straight-through cables and is connected to punch down blocks or terminated by the RJ45 plug, a type of 8P8C modular connector for making connections via a jack installed in networked devices.

Physical specifications of Category 5e cable

Category 5e horizontal patch cable or work area cable is suitable for all Cat5 applications including 10BASE-T, 100BASE-T, and Gigabit Ethernet.

  • It consists of 4 unshielded twisted pair (UTP) wires, set in a cruciform arrangement. Cat 5e cable also carries a stranded copper drain wire for grounding
  • The center conductor of each wire is made from 7 strands of bare copper wire. It has an American Wire Guage (AWG) of 26.
  • The stranded copper wires are covered in colored polyethylene (PE) jacketing which gives each wire a diameter of 0.95mm (0.037 inches).
  • Each twisted pair is color-coded. This enables the wiring of the cable according to standardized wiring patterns. The four pairs of colors are:
    • The first color code pair has a solid blue wire and a striped blue/white wire.
    • The second color code pair has a solid orange wire and a striped orange/white wire.
    • The third color code pair has a solid green wire and a striped green/white wire.
    • The fourth color code pair has a solid brown wire and a striped brown/white wire.
  • The four twisted-pairs are wrapped in Mylar aluminum polyester film that overlaps the cable core. This shielding faces outwards and has contact with the drain wire.
  • The entire Cat5e cable is wrapped in an outer jacket of PVC. It has an overall diameter of 5.0 millimeters (0.196 inches).

Electrical specifications of Category 5e cable

  • Cat5e cable has a characteristic impedance of 100 Ohms.
  • The maximum frequency of the Cat5e cable is 100 MHz.
  • Its mutual capacitance is 5.6nF/100m
  • The conductor resistance of Category 5e cable is less than 9.80Ω/100m.
  • The velocity of propagation of Cat5e cable is 69%.

Attenuation of Cat 5e cable

At 20 degrees Celsius (68 degrees Fahrenheit):
  • At 1 MHz the attenuation of Category 5e cable is 3.2 dB per 100m.
  • At 4 MHz the attenuation of Category 5e cable is 6 dB per 100m.
  • At 10 MHz the attenuation of Category 5e cable is 9.5 dB per 100m.
  • At 16 MHz the attenuation of Category 5e cable is 12.1 dB per 100m.
  • At 20 MHz the attenuation of Category 5e cable is 13.5 dB per 100m.
  • At 31.25 MHz the attenuation of Category 5e cable is 17.1 dB per 100m.
  • At 62.5 MHz the attenuation of Category 5e cable is 24.8 dB per 100m.
  • At 100 MHz the attenuation of Category 5e cable is 32 dB per 100m.

Mechanical characteristics of Cat5e cable

This cable has an operating temperature range of -20 to +70 degrees Celsius (-4 to 158 degrees Fahrenheit). Its maximum pulling strength is 45 Newtons. The minimum bend radius at installation of Category 5 Ethernet cable is 42 millimeters (1.65 inches).

RJ45 Modular connectors for Category 5e cable
Registered Jack 45 connectors terminate Category 5e cable. These are a type of8 position 8 contact (8P8C) modular connector that is used with twisted pair cables. The eight individual wires of a Cat5e cable are fed into the RJ45 plug and each aligned with their corresponding pin. The RJ45 plug is derived from the analog telephone system standards which specified the connector’s original design. The contemporary RJ 45 specification is outlined in the US standard ANSI/TIA-1096-A and the international standard, ISO-8877.

Category 5e cables that have the connector are mated with the 8P8C modular jacks that are housed within devices. The RJ45 jacks carry sprung metal wires that project away from the connector opening. Insertion of the plus leads to electrical contact between the pins from the plug and the complementary wires in the jack that are opposed under spring tension.

High-quality, RoHS compliant Category 5e cables, and accessories

Our selection of Ethernet cables, connectors, and accessories are made with industry-leading fabrication methods from high-quality materials of good provenance. We ensure that our cables are sourced and manufactured using materials and manufacturing that fully complies with the Restriction of Hazardous Substances (RoHS) Directive, European Union legislation that limits the use of hazardous substances like lead or cadmium in electrical and electronic products (EEE).

The use of Tungsten, Tantalum, Tin, and Gold, known as the 3GT metals is also subject to electronics sector legislation. All Ethernet produces are sold in compliance with key conflict minerals legislation that includes:

  • The Conflict Minerals Regulation (2021)
  • Section 1502 of the Dodd-Frank Act

Why is Category 5e cable important?

Category 5e cable is in widespread use in a variety of networking applications with its operation specified in industry-leading protocols and standards. As a critical physical layer component, this type of Ethernet cable determines the electrical properties, security, and data transfer speeds within Ethernet networks that can exceed 1 Gigabit per second. Key contemporary Cat5e cable applications include:

Category 5e cable for Ethernet over twisted pair

Cat5e cable is routinely used for Ethernet over twisted pair technologies. This superseded the use of coaxial cable for making network connections in the earliest form of Ethernet known as Thick Ethernet or 10BASE5. Thick Ethernet proved inflexible and unwieldy when deployed at scale. Even the use of thinner coax with the development of Thin Ethernet or 10BASE2 has a comparatively reduced scope when compared to the use of twisted pair cabling.

The first use of twisted pair cable for Ethernet was in the 1980s with the introduction of StarLAN, the first iteration of IEEE 802.3. Twisted pair cables were already in use for the analog telephone network, with cable runs in many buildings which greatly reduced deployment costs of the new network once twisted pair cables were established as effective for point to point connectivity.

Twisted pair cabling is now a feature of all Ethernet physical layers. The earlier Ethernet standards only used 2 of the 4 twisted pairs in the cable, but novel applications like Power over Ethernet (PoE) discussed below have found other ways of using the other wires.

Category 5e cable for Fast Ethernet (100BASE-TX)

Fast Ethernet (the copper version) delivers data transfer speeds of up to 100 Mbits per second over Category 5e cable. Introduced in 1995, it was the fastest network of its time. The 803.2u standard specifies data transfer over two sets of twisted pairs (4 wires) within the cable. The active wires (green and orange pairs) are terminated in positions 1, 2, 3, and 6 on modular connector pins and must be wired according to either the T568A or T568B wiring standards. One pair is used for each direction of transfer meaning that Fast Ethernet has a full-duplex operation.

100BASE-TX Ethernet networks are often star networks with participant devices connected to a hub, switch, or controller. The maximum cable length for connections is 100 meters (328 feet). Data for transfer is broken up into frames which carry sources and destination addresses to prevent errors and collisions.

Category 5e cable for Gigabit Ethernet (GbE)

Gigabit Ethernet (1 Gig E) is a version of Ethernet that has speeds of one Gigabit per second. It is outlined in the IEEE standard 802.3ab and overtook Fast Ethernet in the late 1990s due to its significant uplift of speeds. The copper of twisted pair cable version is known as 1000BASET and at a minimum must use Category 5 Ethernet cable. Network segment cable lengths for Gigabit Ethernet are limited to 100 meters (328 feet).

1000BASET uses all four twisted pairs in CAT5e cable with simultaneous bi-directional transmissions.

Gigabit Ethernet also uses autonegotiaton. This is a physical layer signaling mechanism that involves connected devices synchronizing their transmission parameters (speed) for the best-optimized performance that can be achieved by both.

Category 5e cable for Audio over Ethernet (AoE

Category 5e cables are also cable of supporting real-time digital audio transmissions and is actively installed in public auditoria and other facilities that require XLR mic level signal coverage or high-quality audio broadcasting. In these applications, Cat5e cable is advantageous as it is designed for long-term installation and routing in public and commercial spaces, and may already have been installed as part of a home network.

The quality and speed of audio transmission are superior to VoIP and AoE has higher fidelity, bitrates, and extremely low latency which makes it advantageous for professional audio. Like standard Ethernet, the digital audio is transferred directly in frames.

There are several open-source and proprietary standards that provide detailed specifications for Audio over Ethernet networks. Most will use Category 5 cable and 1000BASE-TX signaling. Notable Layer 1 protocols for AoE over Cat5e include:

  • Behringers ULTRANET
  • SuperMAC
  • HyperMAC
  • AudioRail

Cat5e cable can also be used as speaker wire or routing for home theater, with some manufacturers even offering RJ45 jacks on speakers.

Category 5e cable for HDBaseT

HDBaseT is a proprietary set of standards for the transfer of audiovisual data over Ethernet cables that are Category 5 and above and terminated by a modular connector like RJ45. It has made the following functionalities available over Cat 5 Ethernet cable:

  • uncompressed ultra-high-definition video over Ethernet
  • digital audio
  • DC power
  • USB 2.0

The standards have been developed by HDBaseT Alliance which includes companies like Samsung, Sony, and LG Electronics as founding members. The first (1.0) specification that was released in 2010 provided a novel solution for home multimedia connectivity. 2019 saw the release of a 3.0 specification which increased the downstream bandwidth available to support the transmission of uncompressed 4K video. Using Ethernet over twisted pair, HDBaseT can also be used for internet access or SmartTV with compatible devices. Up to 7 USB devices can be simultaneously supported using this connectivity protocol. HDBaseT has extremely low latency and transmissions can take place over cable lengths of up to 100 meters (328 feet).

Category 5e cable for Power over Ethernet (PoE)

Power over Ethernet is used to describe a heterogeneous group of standards and protocols that enables DC power to be transferred to devices over twisted pair Ethernet cables like Cate 5e.

Apart from cable the other key components in PoE networks are:

  • Power Sourcing Equipment (PSE) are the devices that provide source power to devices via connected Category 5 Ethernet cable. Network switches (endspan devices) and PoE injectors (midspan devices) are capable of providing power in this way.
  • Powered Devices (PD) receive power via Ethernet cables. Depending on the device application, it may also have integrated backup or auxiliary power.

PoE means that a single Category 5e cable can not only transmit data but also the power to devices including closed-circuit television cameras, VoIP phones, and wireless access points. PoE typically uses two of the 4 signal pairs in Category 5 cable for power transfer with positive voltage transmitted on wires 4 and 5 and negative voltage on wires 7 and 8. Other protocols are capable of transferring power on the same wires that are used for data (Alternative A PoE) and may use all four pairs within a cable (known as 4-pair transmission or 4PPoE).

The IEEE Ethernet protocol 802.3 specifies at least 3 forms of PoE:

  1. 802.3af This original PoE standard, released in 2003, delivers 15.4 Watts of DC power with a minimum voltage of 44 V DC and 350 mA. As some of the transmitted power dissipates in the cable, a wattage of 12.9 Wattage is reliably provided.
  2. 802.3at The 2009 PoE standard known as PoE+, 25.5 Watts of DC power for suitable devices.
  3. 802.3bu was released in 2016 and introduced single-pair power over data lines. This standard was developed for automotive and industrial applications with 10 power classes ranging from 0.5 to 50 Watts.

Frequently asked questions

  • Can Cat 5e cables be used for 2.5GBASE-T or 5GBASE-T Ethernet?

2.5GBASE-T and 5BASE-T deliver Ethernet at speeds of either 2.5 or 5 Gbit per minute as specified in IEEE 802.3bz. They have been developed as a response to demand for faster Ethernet speeds that are comparable to those attained with WiFi. 2.5 Gigabit Ethernet can use existing Gigabit Ethernet infrastructure and can be run reliably over up to 100 meters (328 feet) of Category 5e cable. However, Category 5e cable is not suitable for supporting 5 Gigabit Ethernet, this requires Category 6 cable.

  • Why are category 5e Ethernet cable runs limited to 100 meters (328 feet) in length?

The specified length of Ethernet cables like Cat5e in the leading protocols is limited because of the effects of signal attenuation. When a signal is transmitted along a length of cable, some of the electromagnetic energy transmitted from the source will be dissipated or absorbed by the cable’s environment before it reaches its destination. This reduction in signal is measured as a ratio between the input and output signal strength in decibels per foot or meter of cable length. As the length of the cable increases, the level of attenuation increases. Beyond 100 meters, the performance of the cable may become deranged from its specification.

  • Can a category 5e cable be used to share internet from a PC?

A PC with a wired or wireless internet connection can share its connectivity with another computer directly via an Ethernet cable via suitable jacks on both devices. Simply connect the Category 5e cable from the host PC to the client device. If either device lacks an Ethernet port, a USB/Ethernet adapter can be used. Once the computers are physically connected the network settings of the host computer will need to be reconfigured to allow the client device to use your network.

  • Can CAT 5e cable be installed outdoors?

Ethernet cable can be installed outside and is often used to provide network connectivity between properties. The type of Ethernet cable used for outdoor installations needs to be able to resist the degrading effects of exposure to dirt and dust, moisture, temperature extremes, and solar radiation. Standard Ethernet cable is not suitable as it will quickly degrade, leading to deteriorated network performance and costly downtime. An outdoor Ethernet cable will have the following features that prolong its lifespan and performance in an outside setting:

    • Solid copper wire
    • Rugged weatherproof high-density polyethylene (HDPE) jacketing
    • UV stabilized plastic jacketing

This often makes outdoor Cat5e cable thicker and less flexible than its standard counterpart. The cable connections can also be housed within weatherproof RJ45 glands and jacks which seal the mated connection from ingress of dust and moisture.